The PMP-310 is a compact, air-operated diaphragm pump that feeds dirty oil from a bulk tank into a US Filtermaxx centrifuge at a steady, adjustable rate. Flow is set with air pressure — no electric motor, no bypass valve, and it can be dead-headed (outlet closed) without damage. Its gentle pumping action does not emulsify water or blend contaminants into the oil the way a gear pump does.
Safety
- Shut off and bleed the air supply before connecting, disconnecting or servicing the pump or hoses.
- Never exceed 72 PSI air supply — fluid discharge pressure equals the air pressure supplied.
- Aluminum pump body: never pump halogenated solvents (e.g. methylene chloride, trichloroethane), strong acids or caustics.
- Do not block the air exhaust vent. Ground the tank, pump and centrifuge when transferring diesel or biodiesel.
Specifications
| Item | Specification |
|---|---|
| Pump type | Single-acting pneumatic diaphragm, with air regulator & gauge |
| Max flow rate | 2.6 GPM (158 GPH) |
| Air pressure range | 29 – 72 PSI |
| Max discharge pressure | 72 PSI |
| Max suction lift | 6.5 ft |
| Max discharge height | 13 ft vertical |
| Fluid ports | 1/4" brass hose barbs (in / out) |
| Air inlet | Push-to-connect fitting |
| Pump body / diaphragm | Aluminum alloy / PTFE (Teflon) |
| Max solids size | 0.08 in (5/64") |
| Mounting | Clamp fits a 1/2" diameter shaft |
Compatible with mineral oils, used motor oil, hydraulic oil, diesel, vegetable oil and biodiesel. Contact US Filtermaxx before pumping any other fluid, or oil heated above 150 °F.
Installation
MOUNT THE PUMP VERTICAL — inlet at the bottom, outlet at the top, cast flow arrow pointing UP. The check valves seat by gravity; an inverted or sideways pump will not prime.
- Mount the pump as close to the dirty oil tank as possible (suction hose under 3 ft), ideally below the tank outlet for a flooded inlet. If drawing from the top of a drum, keep suction lift under 6.5 ft.
- Clamp the pump to a rigid, vertical 1/2" diameter rod or post so it cannot rotate or slide.
- Install a shut-off valve on the tank's bottom outlet. Run the suction hose downhill to the pump inlet with no loops, and clamp it tight — a suction-side air leak is the #1 cause of poor flow.
- Run the discharge hose from the pump outlet to the centrifuge inlet and clamp both ends. A shut-off valve at the centrifuge inlet is optional — the pump simply stalls against a closed valve.
- Connect clean, dry shop air to the regulator inlet (a water separator ahead of the regulator is strongly recommended), with a shut-off valve in the air line.
- Before turning on air, back the regulator all the way out and close the air flow adjustment valve.
Hoses are not included. Use oil-resistant hose rated for at least 75 PSI; step up to 3/8" ID on discharge runs longer than 10 ft.
Start-Up & Feed Rate
- Confirm the pump is vertical (arrow up) and all hose clamps are tight. Make sure the centrifuge is ready to receive oil.
- Pull both Work / Drain valves OUT to the Work position.
- Open the tank shut-off valve and the centrifuge inlet valve (if installed).
- Turn on the air, open the air flow valve and slowly raise the regulator to about 30 PSI — the pump should cycle with a steady pulse.
- Increase pressure slowly until the centrifuge reaches its recommended feed rate. Higher pressure = more flow. Do not exceed 72 PSI.
Checking Your Flow Rate
- Time how many seconds the discharge takes to fill a 1-gallon container.
- GPM = 60 ÷ seconds to fill 1 gallon (e.g. 40 seconds = 1.5 GPM / 90 GPH).
- Use the air flow valve for fine adjustment once the regulator is set. Warming cold, thick oil improves both pumping and separation.
Shutdown & Flushing
Turn the regulator down and shut off the air, close the tank valve, then push both Work / Drain valves IN to drain the pump chambers. If the pump will sit idle, flush it with clean diesel or a compatible non-halogenated solvent for 30–60 seconds so sludge cannot harden inside. Pull the valves back OUT before the next start-up.
Maintenance
| Interval | Task |
|---|---|
| Every use | Inspect hoses and clamps for leaks, kinks or cracks; confirm the pump is vertical and secure |
| Daily | Drain water from the air filter / separator bowl; make sure the exhaust vent is clear |
| Before idle periods | Flush the pump; cap the inlet and outlet |
| Every 6 months | Inspect the diaphragm and check valves; replace the diaphragm at the first sign of oil at the exhaust vent |
| Cold storage | Drain completely; store above freezing if it has handled water-contaminated oil |
Troubleshooting
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump does not cycle | No air, air flow valve closed, or regulator set too low | Check air supply; open the valve; raise regulator to at least 30 PSI |
| Pump cycles but no oil | Work / Drain valves pushed IN; tank valve closed or suction leak; pump not vertical; suction lift too high | Pull valves OUT; open valve and tighten suction clamps; remount vertical, arrow UP; lower pump below tank outlet |
| Low or uneven flow | Low air pressure, cold / thick oil, or long / undersized discharge hose | Raise air pressure; warm the oil; shorten the run or use 3/8" ID hose |
| Air bubbles in discharge | Suction-side air leak or low tank level | Tighten suction fittings; keep the tank outlet covered with oil |
| Pump stalls | Discharge valve closed or centrifuge inlet blocked | Normal when the outlet is closed — open the valve or clear the blockage |
| Oil from exhaust vent | Diaphragm failure | Stop the pump; replace the diaphragm — contact US Filtermaxx |
| Ice / frost at exhaust | Moisture in compressed air | Install or drain a water separator ahead of the regulator |