Centrifuge Feed Pump Manual (PMP-310)

Pneumatic Diaphragm Centrifuge Feed Pump

The PMP-310 is a compact, air-operated diaphragm pump that feeds dirty oil from a bulk tank into a US Filtermaxx centrifuge at a steady, adjustable rate. Flow is set with air pressure — no electric motor, no bypass valve, and it can be dead-headed (outlet closed) without damage. Its gentle pumping action does not emulsify water or blend contaminants into the oil the way a gear pump does.

Safety

  • Shut off and bleed the air supply before connecting, disconnecting or servicing the pump or hoses.
  • Never exceed 72 PSI air supply — fluid discharge pressure equals the air pressure supplied.
  • Aluminum pump body: never pump halogenated solvents (e.g. methylene chloride, trichloroethane), strong acids or caustics.
  • Do not block the air exhaust vent. Ground the tank, pump and centrifuge when transferring diesel or biodiesel.

Specifications

Item Specification
Pump type Single-acting pneumatic diaphragm, with air regulator & gauge
Max flow rate 2.6 GPM (158 GPH)
Air pressure range 29 – 72 PSI
Max discharge pressure 72 PSI
Max suction lift 6.5 ft
Max discharge height 13 ft vertical
Fluid ports 1/4" brass hose barbs (in / out)
Air inlet Push-to-connect fitting
Pump body / diaphragm Aluminum alloy / PTFE (Teflon)
Max solids size 0.08 in (5/64")
Mounting Clamp fits a 1/2" diameter shaft

Compatible with mineral oils, used motor oil, hydraulic oil, diesel, vegetable oil and biodiesel. Contact US Filtermaxx before pumping any other fluid, or oil heated above 150 °F.

Installation

MOUNT THE PUMP VERTICAL — inlet at the bottom, outlet at the top, cast flow arrow pointing UP. The check valves seat by gravity; an inverted or sideways pump will not prime.

  1. Mount the pump as close to the dirty oil tank as possible (suction hose under 3 ft), ideally below the tank outlet for a flooded inlet. If drawing from the top of a drum, keep suction lift under 6.5 ft.
  2. Clamp the pump to a rigid, vertical 1/2" diameter rod or post so it cannot rotate or slide.
  3. Install a shut-off valve on the tank's bottom outlet. Run the suction hose downhill to the pump inlet with no loops, and clamp it tight — a suction-side air leak is the #1 cause of poor flow.
  4. Run the discharge hose from the pump outlet to the centrifuge inlet and clamp both ends. A shut-off valve at the centrifuge inlet is optional — the pump simply stalls against a closed valve.
  5. Connect clean, dry shop air to the regulator inlet (a water separator ahead of the regulator is strongly recommended), with a shut-off valve in the air line.
  6. Before turning on air, back the regulator all the way out and close the air flow adjustment valve.

Hoses are not included. Use oil-resistant hose rated for at least 75 PSI; step up to 3/8" ID on discharge runs longer than 10 ft.

Start-Up & Feed Rate

  1. Confirm the pump is vertical (arrow up) and all hose clamps are tight. Make sure the centrifuge is ready to receive oil.
  2. Pull both Work / Drain valves OUT to the Work position.
  3. Open the tank shut-off valve and the centrifuge inlet valve (if installed).
  4. Turn on the air, open the air flow valve and slowly raise the regulator to about 30 PSI — the pump should cycle with a steady pulse.
  5. Increase pressure slowly until the centrifuge reaches its recommended feed rate. Higher pressure = more flow. Do not exceed 72 PSI.

Checking Your Flow Rate

  • Time how many seconds the discharge takes to fill a 1-gallon container.
  • GPM = 60 ÷ seconds to fill 1 gallon (e.g. 40 seconds = 1.5 GPM / 90 GPH).
  • Use the air flow valve for fine adjustment once the regulator is set. Warming cold, thick oil improves both pumping and separation.

Shutdown & Flushing

Turn the regulator down and shut off the air, close the tank valve, then push both Work / Drain valves IN to drain the pump chambers. If the pump will sit idle, flush it with clean diesel or a compatible non-halogenated solvent for 30–60 seconds so sludge cannot harden inside. Pull the valves back OUT before the next start-up.

Maintenance

Interval Task
Every use Inspect hoses and clamps for leaks, kinks or cracks; confirm the pump is vertical and secure
Daily Drain water from the air filter / separator bowl; make sure the exhaust vent is clear
Before idle periods Flush the pump; cap the inlet and outlet
Every 6 months Inspect the diaphragm and check valves; replace the diaphragm at the first sign of oil at the exhaust vent
Cold storage Drain completely; store above freezing if it has handled water-contaminated oil

Troubleshooting

Problem Likely Cause Solution
Pump does not cycle No air, air flow valve closed, or regulator set too low Check air supply; open the valve; raise regulator to at least 30 PSI
Pump cycles but no oil Work / Drain valves pushed IN; tank valve closed or suction leak; pump not vertical; suction lift too high Pull valves OUT; open valve and tighten suction clamps; remount vertical, arrow UP; lower pump below tank outlet
Low or uneven flow Low air pressure, cold / thick oil, or long / undersized discharge hose Raise air pressure; warm the oil; shorten the run or use 3/8" ID hose
Air bubbles in discharge Suction-side air leak or low tank level Tighten suction fittings; keep the tank outlet covered with oil
Pump stalls Discharge valve closed or centrifuge inlet blocked Normal when the outlet is closed — open the valve or clear the blockage
Oil from exhaust vent Diaphragm failure Stop the pump; replace the diaphragm — contact US Filtermaxx
Ice / frost at exhaust Moisture in compressed air Install or drain a water separator ahead of the regulator

View PDF Manual ↗